USA - (800) 526 3867
UK - 44 (0) 1482 646020
Differential Display

Differential Display is a powerful technique for detecting and quantitating changes in gene expression patterns between differently treated cells. Fragments of those genes which are induced or suppressed can be identified and isolated for further analysis, with no prior knowledge of the sequences involved. The technique is PCR based, and yields results in only 1 - 3 days.
Differential Display is a variation of standard PCR, allowing the amplification of a large population of fragments, rather than the specific amplification of one band. Specificity is reduced in two ways. First, random primers are used at one end of the amplification. A mixture of all possible hexamers (46=4096 primers) is used. This allows many different molecules to be amplified.
The second drop in specificity is provided by using the poly A tail present on the vast majority of RNA species. A poly dT primer is used to prime on this tail. The 3' end of the poly dT primer has a pair of non T bases, which is sufficient to "anchor" the primer to the end of the coding sequence. There are thus 32 = 9 different possible primers at this end.
Amplifications run with random hexamers and the poly dT primers on cDNA (that is, DNA copied from mRNA) taken from treated and untreated cells, gives a pattern of bands, each of which represents an amplified fragment of an expressed gene. A fragment which appears in one sample but not the other is either induced or suppressed by the treatment. Such bands may be cut out and re-amplified (using the same primer set as in the original reaction) for further analysis including sequencing, cloning, probe synthesis, etc.
Differential Display
Differential display is a PCR based technique that generates a characteristic set of DNA fragments from the messenger RNA pool within a cell. The use of random hexamers (brown) in combination with oligo-dT primers (blue) allows the amplification of a population of DNA species which changes with the composition of the starting RNA pool. Differential display is a powerful tool for the analysis of gene expression.


Differential display is covered by patents owned by GeneHunter. GeneHunter recommends the use of SequaGel - UreaGel 6 for Differential Display analysis:
GeneHunter Corporation
624 Grassmere Park Dr.
Nashville, TN 37211
(800) 311-8260
genehunt@telalink.net


2


The SequaGel - UreaGel System is RNase Free
SequaGel - UreaGel System

  • Conveniently casts 19:1 denaturing gels
  • Easy to vary monomer percentage from 4-20%
  • Urea already dissolved
  • Certified RNase and DNase free
  • Consistently crystal clear gels


UreaGel - SequaGel - System

REQUEST A CATALOG

CURRENCIES

NEW PRODUCTS

ProtoGel Quick-Cast

Combines the convenience of pre-cast gels with the economy of gel solutions. Ideal for Western Blotting applications
Read more...


Ecoscint Ultra

The best scintillation cocktail on the market for low background, low temperature counting of environmental samples.
Read more...


Hydrogen Peroxide Assay Kit

Rapid, sensitive and quantitative method for the determination of Hydrogen Peroxide in chemical or biological systems.
Read more...

































Copyright © 2010 National Diagnostics. All rights reserved.
Please read our policies on privacy and shipping & returns.  Contact Us.
Powered by OS Commerce