Version 3.0
Date revised: 4/26/2019

SAFETY DATA SHEETNational Diagnostics

Conforms to regulation (EC) no. EU 453/2010

SECTION 1 - IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING

1.1 Product Identifier

Product Name: MES-SDS Running Buffer (20X) Product Number: EC-868

1.2 Relevant Identified Uses of the Substance/Mixture and Uses Advised Against

Investigational research by professional users

1.3 Details of the Supplier of the Safety Data Sheet

Manufacturer
National Diagnostics
305 Patton Drive
Atlanta, GA 30036
(404) 699-2121
(800) 526-3867
info@nationaldiagnostics.com

1.4 Emergency Telephone Number

ChemTel Inc.
Contract number MIS8894340
1-800 255-3924 (United States, Canada, Puerto Rico & US Virgin Islands)
01-800-099-0731 (Mexico)
400-120-0751 (China)
000-800-100-4086 (India)
1-300-954-583 (Australia)
0-800-591-6042 (Brazil)
+1-813-255-3924 (All other regions)

SECTION 2 - HAZARDS IDENTIFICATION

2.1 Classification of the Substance or Mixture

Classification according to Regulation (EC) No. 1272/2008 [EU-GHS/CLP]

H302 - Acute Toxicity-Oral (Category 4)
H312 - Acute Toxicity-Dermal (Category 4)
H315 - Skin Corrosion/Irritation (Category 2)
H319 - Serious Eye Damage/Eye Irritation (Category 2A)
H332 - Acute Toxicity-Inhalation (Category 4)
H335 - Specific Target Organ Toxicity, Single Exposure (Category 3)

2.2 Label Elements

GHS LABEL ELEMENTS AND CLASSIFICATION
GHS Label Elements
Harmful 

WARNING

H302 - Harmful if swallowed
H312 - Harmful in contact with skin.
H315 - Causes skin irritation.
H319 - Causes serious eye irritation.
H332 - Harmful if inhaled.
H335 - May cause respiratory irritation.
P261 - Avoid breathing dust/fume/gas/mist/vapors/spray.
P264 - Wash skin thoroughly after handling.
P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing.
P302+P352 - IF ON SKIN: Wash with plenty of soap and water.

  
  

2.3 Other Hazards

None found.

SECTION 3 - COMPOSITION/INFORMATION ON INGREDIENTS

3.2 Mixture

Chemical Names/Description

Aqueous solution of tris base, sodium dodecyl sufate and 2-(N-morpholino)ethanesulfonic acid


Component List

Component % Comp. CAS # EC # 1278/2008 Classification
Tris-Base10-15 77-86-1  201-064-4 H315, H319, H335
MES20-25 4432-31-9   H302, H312, H315, H320, H332, H335
SDS2 151-21-3   205-788-1 H302, H315, H319, H335


SECTION 4 - FIRST AID MEASURES

4.1 Description of First Aid Measures

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.

Ingestion

Call a physician immediately if significant amounts have been swallowed. Give large amounts of water or milk to drink for dilution effect. Do not induce vomiting.

Skin

Immediately flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eyes

Immediately flush eyes with plenty of water for at least fifteen minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.

4.2 Most Important Symptoms and Effects, Both Acute and Delayed

Inhalation

Tris-Base:

Coughing, shortness of breath.

MES:

No information found.

SDS:

Coughing, shortness of breath. May cause allergic reaction in sensitive individuals.

Ingestion

Tris-Base:

Symptoms may include nausea, vomiting, and diarrhea. Large oral doses may cause weakness, collapse, blood clotting, and coma. The estimated lethal dose of Tris Base is 50 grams dry solid.

MES:

No information found.

SDS:

Nausea and diarrhea.

Skin

Tris-Base:

Redness, itching, and pain.

MES:

No information found.

SDS:

Causes dryness and a rash on continued exposure.

Eyes

Tris-Base:

Redness, itching, and pain.

MES:

No information found.

SDS:

Causes redness and pain.

4.3 Indication of Any Immediate Medical Attention and Special Treatment Needed

Unknown/not applicable

SECTION 5 - FIRE FIGHTING MEASURES

5.1 Extinguishing media

Use media appropriate to the primary cause of fire.

5.2 Special Hazards Arising from the Substance/Mixture

Hazardous Combustion Products

Thermal decomposition products may include toxic oxides of nitrogen and carbon.

Hazardous Decomposition Products

Burning may produce carbon monoxide, carbon dioxide, nitrogen oxides.

Hazardous Polymerization

Will not occur under normal conditions of use (See Sections 10.4 & 10.5).

5.3 Advice for Firefighters

In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other positive pressure mode.

5.4 Further Information

No data available.

SECTION 6 - ACCIDENTAL RELEASE MEASURES

6.1 Personal Precautions

Wear appropriate protective equipment as specified in Section 8.

6.2 Environmental Precautions

Prevent discharge into the environment. Dike spills and stop leakage where practical. Do not allow material to enter drains.

6.3 Methods and Materials for Containment and Cleaning Up

Contain and clean up spill immediately, prevent from entering floor drains. Contain liquids using absorbents. Shovel all spill materials into disposal drum. Scrub spill area with detergent, flush with copious amounts of water.

6.4 References to Other Sections

For disposal information see Section 13. For protective clothing and equipment see Section 8.

SECTION 7 - HANDLING AND STORAGE

7.1 Precautions for Safe Handling

Avoid contact and inhalation. Do not get in eyes, on skin, on clothing. Wash thoroughly after handling.

7.2 Conditions for Safe Storage (including any incompatibles)

Keep in a tightly closed container, stored in a cooled, dry, ventilated area.

Incompatibles

Tris-Base:

No incompatibility data found.

MES:

No incompatibility data found.

SDS:

Strong oxidizers, acids.

7.3 Specific End Uses

Investigational research by professional users

SECTION 8 - EXPOSURE CONTROLS/PERSONAL PRECAUTIONS

8.1 Control Parameters

Component: Tris-Base

ACGIH Threshold Limit Value (TLV):

none established

OSHA Permissable Exposure Limit (PEL):

none established

Component: MES

ACGIH Threshold Limit Value (TLV):

none established

OSHA Permissable Exposure Limit (PEL):

none established

Component: SDS

ACGIH Threshold Limit Value (TLV):

None established

OSHA Permissable Exposure Limit (PEL):

None established

8.2 Exposure Controls

Engineering Controls

A system of local and/or general exhaust is recommended to keep employee exposures low. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source.

Respiratory Protection

For conditions of use where exposure to the dust or mist is apparent, a full-face dust/mist respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.

Eye Protection

Use chemical safety goggles and/or a full face shield where splashing is possible. Maintain eye wash fountain and quick-drench facilities in work area.

Skin Protection

Wear protective gloves and clean body covering clothing.


SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES

9.1 Information on Basic Physical & Chemical Properties

a. AppearanceClear, colorless liquidb. OdorNone
c. Odor ThresholdN.A.d. pH8-9
e. Melting/Freezing Point (oC)0f. Boiling point (oC)104.4
g. Flash Point (oC)N.A.h. Evaporation Rate1
i. FlammabilityN.A.j. Upper/Lower Flammability or Explosive LimitsN.A.
k. Vapor PressureWaterl. Vapor Density (Air = 1)N.A.
m. Relative Density1.05n. Water SolubilityMiscible
o. Partition Coefficient n-octanol/waterMixturep. Autoignition Temperature (oC)N.A.
q. Decomposition Temperature (oC)Not applicable.r. ViscosityNo data available.
s. Explosive PropertiesN.A.t. Oxidizing PropertiesN.A.

SECTION 10 - STABILITY AND REACTIVITY

10.1 Reactivity

No Data

10.2 Chemical Stability

Stable under ordinary conditions of use and storage.

10.3 Possibility of Hazardous Reactions

Will not occur under normal conditions of use (See Sections 10.4 & 10.5).

10.4 Conditions to Avoid

Heat, incompatibles.

10.5 Incompatible Materials

Tris-Base:

No incompatibility data found.

MES:

No incompatibility data found.

SDS:

Strong oxidizers, acids.

10.6 Hazardous Decomposition Products

Burning may produce carbon monoxide, carbon dioxide, nitrogen oxides.

SECTION 11 - TOXICOLOGICAL INFORMATION

Product LD50 Values

Oral Rat LD50 (mg/kg)

No data.

Dermal Rabbit LD50 (mg/kg)

No data.

Component Cancer List Status

 NTP Carcinogen 
 KnownAnticipatedIARC Category
Tris-BaseNoNoNone
MESNoNoNo
SDSNoNoNone

Potential Health Effects

Inhalation

Tris-Base

Causes irritation to the respiratory tract.

MES

No information found, but should be handled as a potential health hazard. May cause irritation to the respiratory tract. Symptoms may include coughing, sore throat, labored breathing, and chest pain.

SDS

Dust causes irritation to the respiratory tract.

Ingestion

Tris-Base

Causes irritation and reddening to the mucous membranes of the mouth, esophagus, and gastrointestinal tract.

MES

No information found, but should be handled as a potential health hazard. May cause irritation to the gastrointestinal tract. Symptons may include nausea, vomiting and diaarrhea.

SDS

Large doses may cause gastrointestinal distress.

Skin

Tris-Base

Causes irritation to the skin.

MES

No information found, but compound should be handled as a potential health hazard. May cause irritation with redness and pain. May be absorbed through the skin with possible systematic effects.

SDS

Mildly irritating to skin. May cause allergic skin reactions.

Eyes

Tris-Base

Causes irritation to the eyes.

MES

No information found, but compound should be handled as a potential health hazard. May cause irritation, redness and pain.

SDS

Causes irritation to the eyes.

Carcinogenicity

Tris-Base

Not listed as a carcinogen by NTP or IARC.

MES

CAS# 4432-31-9: Not listed by ACGIH, IARC, NIOSH, NTP or OSHA.

SDS

Not listed as a known or suspected carcinogen by NTP or IARC.

Mutagenicity

Tris-Base

No information found.

MES

No information available.

SDS

Has caused mutagenic effects on laboratory animals.

Reproductive Toxicity

Tris-Base

No information found.

MES

No information available.

SDS

Has caused mutagenic effects on laboratory animals.

Teratogenic Effects

Tris-Base

No information found.

MES

No information available.

SDS

No information found.

Routes of Entry

Tris-Base

Ingestion.

MES

Ingestion.

SDS

No information found.

Target Organ Statement

Tris-Base

No information available.

MES

No information available.

SDS

Persons with pre-existing skin disorders or impaired respiratory function may be more susceptible to the effects of the substance.

SECTION 12 - ECOLOGICAL INFOMATION

12.1 Toxicity

COMPONENT: Tris-Base

 VertebratesInvertebratesAlgaeMicroorganisms
Aquatic Toxicity
(ppm unless otherwise noted)
LC50 460mg/l (Golden ide)EC50: 59.8 mg/L (Daphnia)EC50: 473mg/l @ 48 hrsCE50>1000mg/L (3hrs)

 BirdsArthropodsPlantsMicroorganisms
Terrestrial Environment Toxicity
(ppm unless otherwise noted)
No dataNo dataNo dataNo data

COMPONENT: MES

 VertebratesInvertebratesAlgaeMicroorganisms
Aquatic Toxicity
(ppm unless otherwise noted)
No dataNo dataNo dataNo data

 BirdsArthropodsPlantsMicroorganisms
Terrestrial Environment Toxicity
(ppm unless otherwise noted)
No dataNo dataNo dataNo data

COMPONENT: SDS

 VertebratesInvertebratesAlgaeMicroorganisms
Aquatic Toxicity
(ppm unless otherwise noted)
The 96 hr LC50 of dodecyl sulfate to Fathead minnows was 29 mg/LLC50 (Ceriodaphnia dubia, 48-hr): 5.55 mg/LEC50>120mg/LIC50 (3 hrs): 480 mg/L

 BirdsArthropodsPlantsMicroorganisms
Terrestrial Environment Toxicity
(ppm unless otherwise noted)
No dataNo dataEC50 (72hr, Cicer arietinum ) 361 mg/LNo data

12.2 Persistence and Degradability

Tris-Base

Readily Biodegradable (>97% degradation at 28 days)

MES

No data

SDS

Readily biodegradable (>95% degradation in 28 days)

12.3 Bioaccumulative Potential

Tris-Base

No data

MES

No data

SDS

No data

12.4 Mobility in Soil

Tris-Base

Log Koc 1.57-1.85

MES

No data

SDS

Log Koc 1.545

12.5 Results of PBT and vPvB Assessment

Tris-Base

Not a PBT or vPvB

MES

No data

SDS

Not PBT vPvB

12.6 Other Adverse Effects

Tris-Base

None

MES

None

SDS

None


SECTION 13 - DISPOSAL CONSIDERATIONS

13.1 Waste Treatment Methods

Offer surplus or non-recyclable product to licensed disposal company. Disposal is subject to user compliance with applicable law and product characteristics at time of disposal. Dispose of packaging as product.


SECTION 14 - TRANSPORT INFORMATION

  ADR/RID IATA IMO DOT
14.1 UN Number N.A.N.A.N.A.N.A.
14.2 Shipping NameNot regulatedNot regulated.Not regulatedNot regulated.
14.3 Hazard ClassN.A.N.A.N.A.N.A.
14.4 Packing GroupN.A.N.A.N.A.N.A.
14.5 Environmental HazardsN.A.N.A.Not regulatedN.A.
14.6 Special PrecautionsN.A.N.A.N.A.N.A.

SECTION 15 - REGULATORY INFORMATION

15.1 Safety, Health and Environmental Regulations/Legislation Specific for the Substance/Mixture

United States

TSCA Regulatory Statement

All intentional ingredients are listed on the TSCA Inventory.

SARA 311/312 Hazard Categories
ComponentFirePressureReactivityAcuteChronic
Tris-BaseNoNoNoYesNo
MESNoNoNoNoNo
SDSNoNoNoYesYes

Europe

EEC Regulatory

All intentional ingredients are listed on the European EINECS Inventory.

SECTION 16 - OTHER INFORMATION

Revisional Updates

4/26/2019 - Updated Section 1.4
5/29/2015 - Updated Sections 2.1 and 3.2
7/7/2013 - Released Version 1.0

NFPA Codes

Health 1   Flammability 0  Reactivity 0

Dangers

Tris-Base

H315 - Causes skin irritation.
H319 - Causes serious eye irritation.
H335 - May cause respiratory irritation.

MES

H302 - Harmful if swallowed
H312 - Harmful in contact with skin.
H315 - Causes skin irritation.
H320 - Causes eye irritation.
H332 - Harmful if inhaled.
H335 - May cause respiratory irritation.

SDS

H302 - Harmful if swallowed
H315 - Causes skin irritation.
H319 - Causes serious eye irritation.
H335 - May cause respiratory irritation.

MANUFACTURER DISCLAIMER: The information given herein is offered in good faith as accurate, but without guarantee. Conditions of the use and suitability of the product for particular uses are beyond our control. All risks of use of the product are therefore assumed by the user. Nothing is intended as a recommendation for uses which infringe valid patents or as extending license under valid patents. Appropriate warnings and safe handling procedures should be provided to handlers and users.